SLM-MR240K-E
24" LCD kit
Features
24" TFT LCD
Operating Temperature:-20°C to +60°C
Storage Temperature:-30°C to +70°C
Optical Bonding:EMI mesh with optical bonding
LED Life Time:50,000 Hours (Min)
EMI/EMC is designed to meet ML-STD-461E/F
Shock is designed to meet MIL-STD-810D
Vibration is designed to meet MIL-STD-810E
Specification
LCD Module
LCD Size | 24 TFT LCD |
Backlight | LED |
Resolution | 1920 x 1200 |
View Angle | ± 89° (H), ±89° (V) |
Luminance | 700 cd/m² (after bonding) |
Contrast Ratio | 1000:1 |
Aspect Ratio | 16:10 |
Response Time | 14 ms |
No. of Color | 1.07B |
Active area | 518.4 x 324 mm |
Pixel Pitch | 0.270 (H) x 0.270 (V) |
LED Life Time | 50,000 Hrs (Min) |
Touch Screen
Touch Type | 5-Wire Resistive Touch |
Viewable Area | 522.4 x 328 mm |
Active Area | 518.4 x 324 mm |
Touch Interface | USB |
Touch Glass | AG/AR Strengthen Glass |
Optical Bonding | EMI mesh with optical bonding |
Touch Drivers | Support Windows, Linux, Mac, etc. |
Environmental
Operating Temperature | -20°C to +60°C (Note) |
Storage Temperature | -30°C to +70°C (Note) |
Humidity | Ta=40°C, 95%RH, non-condensing (Note) |
EMI/EMC | The LCD Kit is designed to meet ML-STD-461E/F for a whole display unit(Note) |
Shock | The LCD Kit is designed to meet MIL-STD-810D for a whole display unit(Note) |
Vibration | The LCD Kit is designed to meet MIL-STD-810E for a whole display unit(Note) |
Altitude above sea level | 0~9144 M (30000 feet)(Note) |
AD Board
Support VGA signal | Color:24 bit / Hor. Frequency:30-80KHZ / Ver. Frequency:50-75HZ |
Support DVI/HDMI signal | Color:24 bit / Hor. Frequency:30-80KHZ / Ver. Frequency:50-75HZ |
Input Interface | VGA / DVI / HDMI (1.3/1.4) / USB / Audio |
Output Interface | 41Pin / 0.5mm LVDS Connector / Wafer 4Pin 2.0mm (R/L x1) AV Output x 1 |
Key Control | Power, Menu, Select, CH+, CH-, Up, Down |
OSD Language | English |
DC Input | DC +12V |
Panel selection | DC+3.3V/+5V/+12V |
Note: To work with mentioned certifications, this LCD Kit has offered the potential to be designed in to grain such certification however it is still depends on the final design of the full unit to pass the test and validation of such certification.