VES-P1201
Features
9 to 36VDC Input
Adjustable 5 Different VDC Outputs
Including 12V/10amp, 15.6V/8amp, 19V/7amp, 19.5V/6amp, 20V/5amp
Input Polarity Reversed Protection
Spade Type Fuse Protection
Non-Isolated Power Supply Module
Specification
Min. | Typ. | Max. | Units | Notes | |
Input Range | 9 | 12/24 | 36 | VDC | Continuous input range. |
Efficiency | 80 | 90 | % | The efficiency should meet >=80% at lowest & highest temperature. | |
Operation Temperature |
-20 | 70 | °C | Derate linearly above 50°C to a maximum temperature of 70°C. |
Dimensions | 139 (L) x 78 (W) x 30 (H) mm, Tolerance +/- 1 mm |
Safety | IEC/EN/UL 62368 |
EMC | EN55032:2015; CISPR32; FCC Part 15, Subpart B: Class B; ICES Issue 7: Class B; RoHS/REACH |
ESD/ Immunity | EN55035 |
Note | Design to meet above standards, this product has offered the potential to be designed in to gain such certification; however, tests and qualifications for certain certifications are needed upon request. The actual efficiency may be affected by final enclosure. |
Input
Min. | Typ. | Max. | Units | Notes | |
Input Voltage | 9 | 12/24 | 36 | VDC | Continuous input range. |
Input Current | 18.5 | A | DC input voltage 9VDC, max load. | ||
Inrush Current |
(TBD) | A | Cold start at 25°C. |
Features |
Input undervoltage protection function, input surge voltage protection function, input current overload protected (fuse protection). |
Output
Min. | Typ. | Max. | Units | Notes | |
Output Voltage (1) +12V |
0 | -- | 10 | Amp | |
Output Voltage (2) +15.6V |
0 | -- | 8 | Amp | |
Output Voltage |
0 | -- | 7 | Amp | |
Output Voltage |
0 | ---- | 6 | Amp | |
Output Voltage |
0 | -- | 5 | Amp | |
Efficiency | -- | 90 | -- | % |
Features |
Output short circuit protection |
Environmental Compliance
Min. | Typ. | Max. | Units | Notes | |
Operating Temperature |
-20 | 70 | °C | Derate linearly above 50°C to a maximum temperature of 70°C. | |
Storage |
-30 | 80 | °C | ||
Operating Humidity |
10 | 90 | %RH | Non-condensing. | |
Storage Humidity |
10 | 95 | %RH |
Note | The above environmental specifications are subject to a proper design of well-ventilated mechanical housing for this power supply, such as a conducted heatsink being used from the housing to the power supply. ACT Power reserve the right to review the design of housing to achieve the final specifications. |
Safety
Details | |
Safety | IEC/EN/UL 62368 |
EMC | EN55032:2015; CISPR32; FCC Part 15, Subpart B: Class B; ICES Issue 7: Class B; RoHS/REACH |
ESD/ Immunity | EN55035 |
Note | Designed to meet the above standards, this product offers the potential to achieve such certification; however, testing and qualification for certain certifications are available upon request. The actual efficiency may be impacted by the final enclosure. |